The contact breaker is a mechanically operated electrical switch which is fixed to the distributor base plate and opened and closed by the distributor cam with the rotation of the engine.
The contacts normally form a self-contained unit, fixed to the base plate by a retaining screw engaged in a slot in the fixed contact.
The slot allows for adjusting the contact breaker gap and setting the dwell angle when fitting or servicing.